The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.
Volzhanin A.V.
Research Institute of Eye Diseases
Petrov S.Yu.
Research Institute of Eye Diseases
Safonova D.M.
Research Institute of Eye Diseases
On refraction shift after trabeculectomy
Journal: Russian Annals of Ophthalmology. 2022;138(5‑2): 147‑155
Views: 1090
Downloaded: 51
To cite this article:
Volzhanin AV, Petrov SYu, Safonova DM, Averich VV. On refraction shift after trabeculectomy. Russian Annals of Ophthalmology.
2022;138(5‑2):147‑155. (In Russ.)
https://doi.org/10.17116/oftalma2022138052147
To determine the factors affecting the shift of refraction after trabeculectomy.
The study included 42 patients who were examined prior to trabeculectomy and at the following timepoints: 1 week, 1 month and 3 months after surgery. Examination included tonometry with assessment of corneal biomechanical properties, keratorefractometry with vector analysis, and biometry. The obtained data was processed for regression analysis and to find the possible correlations.
All significant correlations between the measured parameters only occur on week 1. Postoperative spherical component of refraction (sphere) correlates negatively both with preoperative axial length (AL) and anterior chamber depth (ACD) (r=–0.699 and r=–0.458, p<0.05) and postoperative AL and ACD (r= –0.767 and r= –0.415, p<0.011). Dependence of sphere on AL is also expressed as a regression model. The magnitude of AL change depends on the magnitude of intraocular pressure (IOP) change (r=0.729, p<0.0001) and correlates negatively with postoperative IOP (r=–0.454, p=0.009) and baseline corneal hysteresis (CH; r= –0.482, p=0.009). Dependence of AL on IOP is also expressed as a regression model. The magnitudes of sphere and cylinder shifts correlate negatively with each other (r=–0.416, p=0.038). Keratometry reveals that the overall cylinder value correlates with the corneal cylinder, and so do the magnitudes of their shifts (r=0.589 and r=0.574, p<0.0001). Dependence of corneal hysteresis on IOP is expressed as a regression model; however, neither tonometric nor biomechanical corneal properties correlate with refraction.
Sphere correlates negatively with AL and ACD. In turn, AL is related to the reduction in IOP. This dependence is likely the most important one for the refraction shift after trabeculectomy. No correlations were found for the change of astigmatism.
Keywords:
Authors:
Volzhanin A.V.
Research Institute of Eye Diseases
Petrov S.Yu.
Research Institute of Eye Diseases
Safonova D.M.
Research Institute of Eye Diseases
Received:
13.10.2021
Accepted:
26.02.2022
List of references:
Close metadata
Email Confirmation
An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.
Email Confirmation
Log in to the site using your account in one of the services
We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.