The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Kalinin R.E.

Ryazan State Medical University

Suchkov I.A.

Ryazan State Medical University

Mzhavanadze N.D.

Pavlov Ryazan State Medical University

Povarov V.O.

Pavlov Ryazan State Medical University

Quality of Life in Patients with Venous Thromboembolism after Pacemaker Implantation

Authors:

Kalinin R.E., Suchkov I.A., Mzhavanadze N.D., Povarov V.O.

More about the authors

Journal: Journal of Venous Disorders. 2020;14(3): 191‑195

Read: 1950 times


To cite this article:

Kalinin RE, Suchkov IA, Mzhavanadze ND, Povarov VO. Quality of Life in Patients with Venous Thromboembolism after Pacemaker Implantation. Journal of Venous Disorders. 2020;14(3):191‑195. (In Russ.)
https://doi.org/10.17116/flebo202014031191

Recommended articles:
Effi­ciency of complex medi­cal reha­bilitation after pulmonary enda­rterectomy. Russian Journal of Cardiology and Cardiovascular Surgery. 2024;(6):629-636
Simu­ltaneous auto­plastic repair and diastasis recti correction for linea alba hernias. Russian Journal of Evidence-Based Gastroenterology. 2024;(4):34-39

References:

  1. Kalinin RE, Suchkov IA, Mzhavanadze ND, Shitov II, Povarov VO. Venous thromboembolism in patients with cardiac implantable electronic devices. Angiologiya i sosudistaya khirurgiya. 2017;23(4):69-74. (In Russ.)
  2. Boczar K, Ząbek A, Haberka K, Hardzina M, Dębski M, Rydlewska A, Nowosielska-Ząbek E, Lelakowski J, Małecka B. Venous Stenosis and Occlusion in the Presence of Endocardial Leads. Advances in Clinical and Experimental Medicine. 2016;25(1):83-91.  https://doi.org/10.17219/acem/42317
  3. Santini M, Di Fusco SA, Santini A, Magris B, Pignalberi C, Aquilani S, Colivicchi F, Gargaro A, Ricci RP. Prevalence and predictor factors of severe venous obstruction after cardiovascular electronic device implantation. Europace. 2015;18(8):1220-1226. https://doi.org/10.1093/europace/euv391
  4. Serdyukov DA, Egorov DF, Yudina OV. Thromboembolic complications of permanent pacing. Vestnik aritmologii. 2008;54(48):48-54. (In Russ.)
  5. Stofmeel MA, Post MW, Kelder JC, Grobbee DE, van Hemel NM. Changes in quality-of-life after pacemaker implantation: responsiveness of the Aquarel questionnaire. Pacing Clin Electrophysiol. 2001;24(3):288-295.  https://doi.org/10.1046/j.1460-9592.2001.00288.x
  6. Stofmeel MA, Post MW, Kelder JC, Grobbee DE, van Hemel NM. Psychometric properties of Aquarel. A disease-specific quality of life questionnaire for pacemaker patients. J Clin Epidemiol. 2001;54(2):157-165.  https://doi.org/10.1016/s0895-4356(00)00275-4
  7. Lelakowski J, Domagała TB, Rydlewska A, Januszek R, Kotula-Horowitz K, Majewski J, Ząbek A, Małecka B. Relationship between changes in selected thrombotic and inflammatory factors, echocardiographic parameters and the incidence of venous thrombosis after pacemaker implantation based on our own observations. Archives of Medical Science. 2012;20(6):1027-1034. https://doi.org/10.5114/aoms.2012.28600
  8. Crook BR, Gishen P, Robinson CR, Oram S. Occlusion of the subclavian vain associated with cephalic vein pacemaker electrodes. Br J Surg. 1977; 64(5):329-331.  https://doi.org/10.1002/bjs.1800640508
  9. Kar AK, Ghosh S, Majumdar A, Mondal M, Dutta I. Venous obstruction after permanent pacing. Indian Heart J. 2000;52(4):431-433. 
  10. Pieper CC, Weis V, Fimmers R, Rajab I, Linhart M, Schild HH, Nähle CP. Venous obstruction in asymptomatic patients undergoing first implantation or revision of a cardiac pacemaker or implantable cardioverter-defibrillator: a retrospective single center analysis. Rofo. 2015;187(11):1029-1035. https://doi.org/10.1055/s-0035-1553351
  11. Mongridiene A, Kursvietiene L, Kasauskas A. The coagulation system changes in patients with chronic heart failure. Medicina (Kaunas). 2010; 46(9):642-647. 
  12. Kalinin RE, Suchkov IA, Mzhavanadze ND, Povarov VO. Dynamics of Coagulation Parameters and Their Relationship with Venous Thromboembolic Events in Patients with Cardiac Implantable Electronic Devices. Flebologiya. 2019; 13(1):21-27. (In Russ.) https://doi.org/10.17116/flebo20191301121
  13. Udo EO, van Hemel NM, Zuithoff NP, Nijboer H, Taks W, Doevendans PA, Moons KG. Long term quality-of-life in patients with bradycardia pacemaker implantation. Int J Cardiol. 2013;168(3):2159-2163. https://doi.org/10.1016/j.ijcard.2013.01.253
  14. Fleischmann KE, Orav EJ, Lamas GA, Mangione CM, Schron E, Lee KL, Goldman L. Pacemaker implantation and quality of life in the Mode Selection Trial (MOST). Heart Rhythm. 2006;3(6):653-659.  https://doi.org/10.1016/j.hrthm.2006.02.1031
  15. Nuzhny VP, Shmakov DN, Azarov YaE, Nuzhnaya TG, Nuzhny PV. Quality of life for patients with implanted pacemaker systems. Annaly aritmologii. 2008;5(1):75-82. (In Russ.)

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.