Kochergin N.A.

Research Institute of Complex Problems of Cardiovascular Diseases, Kemerovo, Russia

Vakkosov K.M.

State Research Institute for Complex Issues of Cardiovascular Diseases, Sosnovy Boulevard, Kemerovo, Russia

Ganjukov V.I.

State Research Institute for Complex Issues of Cardiovascular Diseases, Sosnovy Boulevard, Kemerovo, Russia

Tarasov R.S.

State Research Institute for Complex Issues of Cardiovascular Diseases Municipal Budget Healthcare Institution, Kemerovo, Russia

Shloydo E.A.

Clinical Hospital №2, St. Petersburg, Russia

Transcatheter aortic valve implantation under extracorporeal membrane oxygenation

Authors:

Kochergin N.A., Vakkosov K.M., Ganjukov V.I., Tarasov R.S., Shloydo E.A.

More about the authors

Journal: Pirogov Russian Journal of Surgery. 2019;(4): 66‑71

Read: 1367 times


To cite this article:

Kochergin NA, Vakkosov KM, Ganjukov VI, Tarasov RS, Shloydo EA. Transcatheter aortic valve implantation under extracorporeal membrane oxygenation. Pirogov Russian Journal of Surgery. 2019;(4):66‑71. (In Russ.)
https://doi.org/10.17116/hirurgia201904166

Recommended articles:
Cere­bral protection in transcatheter aortic valve implantation. Piro­gov Russian Journal of Surgery. 2024;(12-2):150-158
Predictors and impact of myocardial injury (VARC-3 criteria) after transcatheter aortic valve implantation. Russian Journal of Cardiology and Cardiovascular Surgery. 2024;(5):489-498
Predictors of aortic valve dysfunction after the Ozaki procedure. Russian Journal of Cardiology and Cardiovascular Surgery. 2024;(6):624-628
Aortic homo­graft in redo aortic root surgery. Russian Journal of Cardiology and Cardiovascular Surgery. 2024;(6):686-690
Imme­diate resu­lts of mitral and aortic valve replacement with simu­ltaneous Cox-Maze IV procedure. Russian Journal of Cardiology and Cardiovascular Surgery. 2025;(1):28-33

References:

  1. Gajfulin RA, Sumin AN, Ivanov SV, Barbarash LS. Survival after surgical treatment of multifocal atherosclerosis in different age groups. Complex Issues of Cardiovascular Diseases. 2017;2(6):6-18. (In Russ.)
  2. Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364:2187-2198. https://doi.org/10.12968/bjca.2011.6.11.564a
  3. Leon MB, Smith CR, Mack MJ, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374:1609-1620. https://doi.org/10.1056/NEJMoa1514616
  4. Waksman R, Pichard AD. Will TAVR become the default treatment for patients with severe aortic stenosis? J Am Coll Cardiol. 2015;66:122-124. https://doi.org/10.1016/j.jacc.2015.05.016
  5. Husser O, Pellegrini C, Kessler T, et al. Outcomes after transcatheter aortic valve replacement using a novel balloonexpandable transcatheter heart valve: A single-center experience. JACC Cardiovasc Interv. 2015;8:1809-1816. https://doi.org/10.1016/j.jcin.2015.08.01
  6. Thourani VH, Kodali S, Makkar RR, et al. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: A propensity score analysis. Lancet. 2016;387:2218-2225. https://doi.org/10.1016/S0140-6736(16)30073-3
  7. Eggebrecht H, Bestehorn M, Haude M, et al. Outcomes of transfemoral transcatheter aortic valve implantation at hospitals with and without on-site cardiac surgery department: Insights from the prospective German aortic valve replacement quality assurance registry (AQUA) in 17 919 patients. Eur Heart J. 2016;37:2240-2248. https://doi.org/10.1093/eurheartj/ehw190
  8. Kuck KH, Eggebrecht H, Figulla HR, et al. Quality criteria on the implementation of transcatheter aortic valve implantation (TAVI). Position paper of the German Society of Cardiology. Der Kardiol. 2015;9:11-26. https://doi.org/10.1016/j.jcin.2012.04.001
  9. Holmes DR Jr, Mack MJ, Kaul S, et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol. 2012;59:1200-1254. https://doi.org/10.1016/j.athoracsur.2012.01.084
  10. Husser O, Holzamer A, Philipp A, et al. Emergency and prophylactic use of miniaturized veno-arterial extracorporeal membrane oxygenation in transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2013;82:E542-E551. https://doi.org/10.1002/ccd.24806
  11. Seco M, Forrest P, Jackson SA, et al. Extracorporeal membrane oxygenation for very high-risk transcatheter aortic valve implantation. Heart Lung Circ. 2014;23:957-962. https://doi.org/10.1016/j.hlc.2014.05.006
  12. Singh V, Patel SV, Savani C, et al. Mechanical circulatory support devices and transcatheter aortic valve implantation (from the National Inpatient Sample). Am J Cardiol. 2015;116:1574-1580. https://doi.org/10.1016/j.amjcard.2015.08.020
  13. Trenkwalder T, Pellegrini C, Holzamer A, et al. Emergency extracorporeal membrane oxygenation in transcatheter aortic valve implantation: A two-center experience of incidence, outcome and temporal trends from 2010 to 2015. Catheter Cardiovasc Interv. 2017;00:1-8. https://doi.org/10.1002/ccd.27385
  14. Bax JJ, Delgado V, Bapat V, et al. Open issues in transcatheter aortic valve implantation. Part 1: Patient selection and treatment strategy for transcatheter aortic valve implantation. Eur Heart J. 2014;35:2627-2638. https://doi.org/10.1093/eurheartj/ehu257
  15. Tamborini G, Fusini L, Gripari P, et al. Feasibility and accuracy of 3DTEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation. JACC Cardiovasc Imaging. 2012;5:579-588. https://doi.org/10.1016/j.jcmg.2012.02.012
  16. Husser O, Holzamer A, Resch M, et al. Prosthesis sizing for transcatheter aortic valve implantation. Comparison of three dimensional transesophageal echocardiography with multislice computed tomography. Int J Cardiol. 2013;168:3431-3438. https://doi.org/10.1016/j.ijcard.2013.04.182
  17. Seiffert M, Conradi L, Baldus S, et al. Severe intraprocedural complications after transcatheter aortic valve implantation: Calling for a heart team approach. Eur J Cardiothorac Surg. 2013;44:478-484. https://doi.org/10.1093/ejcts/ezt032
  18. Walther T, Hamm CW, Schuler G, et al. Perioperative results and complications in 15,964 transcatheter aortic valve replacements: Prospective data from the GARY registry. J Am Coll Cardiol. 2015;65:2173-2180. https://doi.org/10.1016/j.jacc.2015.03.034
  19. Hein R, Abdel-Wahab M, Sievert H, et al. Outcome of patients after emergency conversion from transcatheter aortic valve implantation to surgery. EuroIntervention. 2013;9:446-451. https://doi.org/10.4244/EIJV9I4A73
  20. Toutouzas K, Synetos A, Latsios G, et al. The requirement of extracorporeal circulation system for transluminal aortic valve replacement: Do we really need it in the catheterization laboratory? Catheter Cardiovasc Interv. 2015. https://doi.org/10.1002/ccd.25988
  21. Makkar RR, Jilaihawi H, Chakravarty T, et al. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: A study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve). J Am Coll Cardiol. 2013;62:418-430. https://doi.org/10.1016/j.jacc.2013.04.037
  22. Kodali S, Thourani VH, White J, et al. Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediaterisk patients with aortic stenosis. Eur Heart J. 2016;37:2252-2262. https://doi.org/10.1093/eurheartj/ehw112
  23. Shreenivas SS, Lilly SM, Szeto WY, et al. Cardiopulmonary bypass and intra-aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: A PARTNER trial substudy. Catheter Cardiovasc Interv. 2015;86:316-322. https://doi.org/10.1002/ccd.25776
  24. Singh V, Damluji AA, Mendirichaga R, et al. Elective or emergency use of mechanical circulatory support devices during transcatheter aortic valve replacement. J Interv Cardiol. 2016;29:513-522. https://doi.org/10.1111/joic.12323
  25. Werdan K, Gielen S, Ebelt H, Hochman JS. Mechanical circulatory support in cardiogenic shock. Eur Heart J. 2014;35:156-167. https://doi.org/10.1093/eurheartj/eht248
  26. Ribeiro HB, Nombela-Franco L, Urena M, et al. Coronary obstruction following transcatheter aortic valve implantation: A systematic review. JACC Cardiovasc Interv. 2013;6:452-461. https://doi.org/10.1016/j.jcin.2012.11.014
  27. Barbanti M, Yang TH, Rodes Cabau J, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128:244-253. https://doi.org/10.1161/CIRCULATIONAHA.113.002947
  28. Aubron C, Cheng AC, Pilcher D, et al. Factors associated with outcomes of patients on extracorporeal membrane oxygenation support: A 5- year cohort study. Crit Care. 2013;17:R73-R85. https://doi.org/10.1186/cc12681