TachoСomb in practice of cardiovascular surgeon

Authors:

Belov Yu.V., Charchian É.R., Salagaev G.I.

More about the authors

Read: 942 times


To cite this article:

Belov YuV, Charchian ÉR, Salagaev GI. TachoСomb in practice of cardiovascular surgeon. Russian Journal of Cardiology and Cardiovascular Surgery. 2016;9(5):82‑86. (In Russ.)
https://doi.org/10.17116/kardio20169582-86

Recommended articles:
Opti­mal cardioplegia for coro­nary artery bypass grafting in patients with heart failure: a randomized study. Russian Journal of Cardiology and Cardiovascular Surgery. 2025;(4):405-411
Surgical treatment of constrictive peri­carditis: a single-center expe­rience. Russian Journal of Cardiology and Cardiovascular Surgery. 2025;(6):703-706
Surgical remo­val of a floating thro­mbus in aortic arch. Russian Journal of Cardiology and Cardiovascular Surgery. 2026;(1):102-107
Prevention of acute kidney injury in cardiac surgery. Russian Journal of Anesthesiology and Reanimatology. 2025;(2):83-89
Gastrointestinal tract protection with nitric oxide in aortic arch surgery: a randomized study. Russian Journal of Anesthesiology and Reanimatology. 2025;(4):13-20

References:

  1. Harmon DE. Cost/benefit analysis of pharmacologic hemostasis. Ann Thorac Surg. 1996;61(2 Suppl):S21-S25.
  2. Shore-Lesserson L, Reich DL, Silvay G, Griepp RB. Hemostasis in aortic and cardiothoracic surgery. J Card Surg. 1997;12(2 Suppl):232-237.
  3. Ranucci M, Bozzetti G, Ditta A, Cotza M, Carboni G, Ballotta A. Surgical reexploration after cardiac operations: why a worse outcome? Ann Thorac Surg. 2008;86(5):1557-1562.
  4. Despotis GJ, Avidan MS, Hogue JrCW. Mechanisms and attenuation of hemostatic activation during extracorporeal circulation. Ann Thorac Surg. 2001;72:S1821-S1823.
  5. Sniecinski RM, Chandler WL. Activation of the hemostatic system during cardiopulmonary bypass. Anesth Analg. 2011;113(6):1319-1333.
  6. Hartmann M, Sucker C, Boehm O, Koch A, Loer S, Zacharowski K. Effects of cardiac surgery on hemostasis. Transfus Med Rev. 2006;20:230-241.
  7. Ja´mbor C, Bremerich D, Moritz A, Seifried E, Zwissler B. Management of hemostasis disorders after extracorporeal circulation: a clinical therapy algorithm. Anaesthesist. 2008;57:374-381.
  8. Baumann P, Schumacher H, Husing J, Luntz S, Knaebel HP: A randomized, controlled, prospective trial to evaluate the haemostatic effect of Lyostypt versus Surgicel in arterial bypass anastomosis: «COBBANA» trial. Trials. 2009;10(1):91.
  9. Kjaergard HK, Fairbrother JE. Controlled clinical studies of fibrin sealant in cardiothoracic surgery - a review. Eur J Cardiothorac Surg. 1996;10:727-733.
  10. Oz MC, Cosgrove III DM, Badduke BR, Hill JD, Flannery MR, Palumbo R, Topic N, The Fusion Matrix Study Group. Controlled clinical trial of a novel hemostatic agent in cardiac surgery. Ann Thorac Surg. 2000;69:1376-1382.
  11. Chapman WC, CoStasis Multi-center Collaborative Writing Committee. A novel collagen-based composite offers effective hemostasis for multiple surgical indications: results of a randomized controlled trial. Surgery. 2001;129:445-450.
  12. Lowe J, Luber J, Levitsky S, Hantak E, Montgomery J, Schiestl N, Schofield N, Marra S, TISSEEL Clinical Study Group. Evaluation of the topical hemostatic efficacy and safety of TISSEELVH S/D fibrin sealant compared with currently licensed TISSEELVH in patients undergoing cardiac surgery: a phase 3, randomized, double-blind clinical study. J Cardiovasc Surg (Torino). 2007;48:323-331.
  13. Lawson JH, Lynn KA, Vanmatre RM, et al. Antihuman factor V antibodies after use of relatively pure bovine thrombin. Ann Thorac Surg. 2005;79(3):1037-1038.
  14. Adelmann-Grill BC, Otto K. Immunological safety evaluation of a haemostatic agent and wound dressing made of horse collagen fibrils. Drug Res. 1987;37:802-805.
  15. Bajardi G, Pecoraro F, Mirabella D. Efficacy of TachoSil patches in controlling Dacron suture-hole bleeding after abdominal aortic aneurysm open repair. J Cardiothorac Surg. 2009 Nov 4;4:60.  doi: 10.1186/1749-8090-4-60
  16. Schelling G, Block T, Gokel M, Blanke E, Hammer C, Brendel W. Application of a fibrinogen-thrombin-collagen based hemostyptic agent in experimental injuries of the liver and spleen. J Trauma. 1988;28:472-475.
  17. Czerny M, Verrel F, Weber H, Muller N et al. Collagen patch coated with fibrin components. Treatment of suture hole bleeding in vascular reconstruction. J Cardiovasc Surg (Torino). 2000;41(4):553-557.
  18. Agus GB, Bono AV, Mira E, et al. Haemostatic efficacy and safety of TachoComb H in surgery. Ready to use and rapid haemostatic agent. Int Surg. 1996;81(3):316-319.
  19. Maisano F, Kjaergеrd HK, Bauernschmitt R, Pavie A, Rбbago G, Laskar M, et al. TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. Eur J Cardiothorac Surg. 2009;36(4):708-714.
  20. Schiele U, Kuntz G, Riegler A. Haemostyptic preparations on the basis of collagen alone and as fixed combination with fibrin glue. Clin Mater. 1992;9:169-177.
  21. Carbon RT. Evaluation of biodegradable fleece-bound sealing: history, material science, and clinical application in tissue engineering and biodegradable equivalents. In: Lewandrowski K-U, Wise DL, Trantolo DJ, Gresser JD, Yaszemski MJ, Altobelli DE, editors. Scientific and clinical applications. Marcel Dekker. 2002;587-650.
  22. Erdogan D, de Graaf W, van Gulik TM. Adhesive strength of fibrinogencoated collagen patch or liquid fibrin sealant in an experimental liver resection model in pigs. Eur Surg Res. 2008;41:298-302.
  23. Carney WI, et al. Intraoperative evaluation of PTFE, Dacron and autogenous vein as carotid patch materials. Ann Vasc Surg. 1987;1(5):583-586.
  24. Joseph T., et al. Randomised Controlled Trial to Evaluate the Efficacy of TachoComb H Patches in Controlling PTFE Suture-hole Bleeding. Eur J Vasc Endovasc Surg. 2004;27:549-552.
  25. Bjork V, Henze A, Rodriguez L. Left ventricular rupture as a complication of mitral valve replacement. J Thorac Cardiovasc Surg. 1977;73:14-22.
  26. Karlson K, Ashraf M, Berger R. Rupture of left ventricle following mitral valve replacement. Ann Thorac Surg. 1988;46:590-597.
  27. Savage D, Garrison R, Brand F, Anderson S, Castelli W, Kannel W, et al. Prevalence and correlates of posterior extra echocardiographic spaces in a free-living population based sample (the Framingham study). Am J Cardiol. 1983;51:1207-1212.
  28. Iemura J, Oku H, Otaki M, Kitayama H, Inoue T, Kaneda T: Surgical strategy for left ventricular free wall rupture after acute myocardial infarction. Ann Thorac Surg. 2001;71:201-204.
  29. Muto A, Nishibe T, Kondo Y, Sato M, Yamashita M, Ando M. Sutureless repair with TachoComb sheets for oozing type postinfarction cardiac rupture. Ann Thorac Surg. 2005;79:2143-2145.
  30. Campbell NC, Thomson SR, Muckart DJ, Meumann CM, Van Middelkoop I, Botha JB. Review of 1198 cases of penetrating cardiac trauma. Br J Surg. 1997;84:1737-1740.
  31. Figueras J, Alcalde O, Barrabйs JA, et al. Changes in hospital mortality rates in 425 patients with acute ST- elevation myocardial infarction and cardiac rupture over a 30-year period. Circulation. 2008;118:2783-2789.
  32. Zoffoli G, Battaglia F, Venturini A, et al. A novel approach to ventricular rupture: clinical needs and surgical technique. Ann Thorac Surg. 2012;93:1002-1003.
  33. Yoshitatsu M, Nomura F, Katayama A, Tamura K, Katayama K, Ihara K, Nakashima Y. Pathologic findings of aortic redissection after glue repair of proximal aorta. J Thorac Cardiovasc Surg. 2004;127:593-595.
  34. Iha K, Ikemura R, Higa N, Akasaki M, Kuniyoshi Y, Koja K. Left ventricular pseudoaneurysm after sutureless repair of subacute left ventricular free wall rupture: a case report. Ann Thorac Cardiovasc Surg. 2001;7:311-314.
  35. Kaplan M, Baysal K. In vitro toxicity test of ethyl 2-cyanoacrylate, a tissue adhesive used in cardiovascular surgery, by fibroblast cell culture method. Heart Surg Forum. 2005;8:E169-E172.
  36. Padro JM, Mesa JM, Silvestre J, Larrea JL, Caralps JM, Cerron F, Aris A. Subacute cardiac rupture: repair with a sutureless technique. Ann Thorac Surg. 1993;55:20-24.
  37. Schuetz A, Schulze C, Wildhirt SM. Off-pump epicardial tissue sealing – a novel method for atrioventricular disruption complicating mitral valve procedures. Ann Thorac Surg. 2004;78:569-574.
  38. Kirklin JW. Left ventricular aneurysm. In: Kirklin JW, Barrat-Boyes BG, eds. Cardiac Surgery. 3rd edition. New York: Churchill Livingstone. 2003;437-455.
  39. Reardon MJ, Carr CL, Diamond A, Letsou GV, Safi HJ, Espada R, Baldwin JC: Ischemic left ventricular free wall rupture: prediction, diagnosis, and treatment. Ann Thorac Surg. 1997;64:1509-1613.
  40. Sutherland FW, Guell FJ, Pathi VL, Naik SK. Postinfarction ventricular free wall rupture: strategies for diagnosis and treatment. Ann Thorac Surg. 1996;61:1281-1285.
  41. Stiegel M, Zimmern SH, Robicsek F. Left ventricular rupture following coronary occlusion treated by streptokinase infusion: successful surgical repair. Ann Thorac Surg. 1987;44:413-415.
  42. Nishizaki K, Seki T, Fujii A, Nishida Y, Funabiki M, Morikawa Y. Sutureless patch repair for small blowout rupture of the left ventricle after myocardial infarction. Jpn J Thorac Cardiovasc Surg. 2004;52:268-271.
  43. Fukushima S, Kobayashi J, Tagusari O, Sasako Y. A huge pseudoaneurysm of the left ventricle after simple gluing of an oozing-type postinfarction rupture. Interact Cardiovasc Thorac Surg. 2003;2:94-96.
  44. Kimura N, Kawahito K, Murata S, Yamaguchi A, Adachi H, Ino T. Pitfalls of sutureless repair of a blow-out type left ventricular free wall rupture. Jpn J Thorac Cardiovasc Surg. 2005;53:382-385.
  45. Amano H, Ohara K, Nie M, et al. New surgical technique of left ventricular free wall rupture: double patch sealing method. Ann Thorac Cardiovasc Surg. 2002;8:389-392.
  46. Fujimatsu T, Oosawa H, Takai F, et al. Patch-and-glue sutureless repair for blowout rupture after myocardial infarction: report of two cases. Ann Thorac Cardiovasc Surg. 2008;14:48-51.
  47. Yamaguchi H, et al. Off-pump suture repair of left ventricular rupture utilizing TachoComb sheet: a case report and literature review. World Journal of Emergency Surgery. 2013;8:29.
  48. Haas S. The Use of a Surgical Patch Coated With Human Coagulation Factors in Surgical Routine: A Multicenter Postauthorization Surveillance. Clinical and Applied Thrombosis/Hemostasis. 2006 October;12:4:445-450.
  49. Czerny M, Fleck T, Salat A, et al. Sealing of the mediastinum with a local hemostyptic agent reduces chest tube duration after complete mediastinal lymph node dissection for stage I and II non-small cell lung carcinoma. Ann Thorac Surg. 2004;77:1028-1032.