The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Sharobaro V.I.

Sechenov First Moscow State Medical University

Karepetyan G.E.

Voino-Yasenetsky Krasnoyarsk State Medical University

Kononets O.A.

Sechenov First Moscow State Medical University (Sechenov University)

Rozova D.K.

Sechenov First Moscow State Medical University (Sechenov University)

Burdin S.A.

Sechenov First Moscow State Medical University (Sechenov University)

Correction of problems associated with breast implants

Authors:

Sharobaro V.I., Karepetyan G.E., Kononets O.A., Rozova D.K., Burdin S.A.

More about the authors

Journal: Plastic Surgery and Aesthetic Medicine. 2025;(1): 116‑123

Read: 1174 times


To cite this article:

Sharobaro VI, Karepetyan GE, Kononets OA, Rozova DK, Burdin SA. Correction of problems associated with breast implants. Plastic Surgery and Aesthetic Medicine. 2025;(1):116‑123. (In Russ., In Engl.)
https://doi.org/10.17116/plast.hirurgia2025011116

Recommended articles:
Subperimetric augmentation mammoplasty: long-term resu­lts. Plastic Surgery and Aesthetic Medi­cine. 2024;(4-2):14-22
Capsular contracture after reco­nstructive plastic surgery for breast cancer. P.A. Herzen Journal of Onco­logy. 2024;(6):78-83
Repeated breast reco­nstruction after previous complications. Piro­gov Russian Journal of Surgery. 2025;(6):51-57

References:

  1. de Benito J, Sanchez K. Secondary breast augmentation: managing each case. Aesthetic Plast Surg. 2010 Dec;34(6):691-700. Epub 2010 Apr 17. PMID: 20838791; PMCID: PMC2993901. https://doi.org/10.1007/s00266-010-9510-1
  2. International Society of Aesthetic Plastic Surgery. 2017. ISAPS International Survey on aesthetic/cosmetic procedures performed in 2017. https://www.isaps.org/media/a0qfm4h3/isaps-global-survey_2022.pdf
  3. Nahabedian MY. Round Form-Stable Breast Implants: Diagnosis and Management of Complications. Plast Reconstr Surg. 2019 July;144(1S Utilizing a Spectrum of Cohesive Implants in Aesthetic and Reconstructive Breast Surgery):73S-81S. PMID: 31246764. https://doi.org/10.1097/PRS.0000000000005953
  4. Wiener TC. Relationship of incision choice to capsular contracture. Aesthetic Plast Surg. 2008 Mar;32(2):303-306. PMID: 17994260. https://doi.org/10.1007/s00266-007-9061-2
  5. Tebbetts JB. Patient evaluation, operative planning, and surgical techniques to increase control and reduce morbidity and reoperations in breast augmentation. Clin Plast Surg. 2001 July;28(3):501-521. PMID: 11471957. https://doi.org/10.1016/S0094-1298(20)32391-9
  6. Araco A, Gravante G, Araco F, Delogu D, Cervelli V, Walgenbach K. A retrospective analysis of 3,000 primary aesthetic breast augmentations: postoperative complications and associated factors. Aesthetic Plast Surg. 2007 Sept-Oct; 31(5):532-539. Epub 2007 July 20. PMID: 17659411. https://doi.org/10.1007/s00266-007-0162-8
  7. Nava MB, Rancati A, Angrigiani C, Catanuto G, Rocco N. How to prevent complications in breast augmentation. Gland Surg. 2017;6(2):210-217.  https://doi.org/10.21037/gs.2017.04.02
  8. Ventura OD, Marino H, Marcello GA. Treatment of the fibrous capsule on mammary implants: a technical innovation for changing the implant from the subglandular to the submuscular plane. Aesthetic Plast Surg. 2008 Mar; 32(2):365-367. PMID: 18027013. https://doi.org/10.1007/s00266-007-9056-z
  9. Tebbetts JB. Breast augmentation with full-height anatomic saline implants: the pros and cons. Clin Plast Surg. 2001 July;28(3):567-577. PMID: 11471962. https://doi.org/10.1016/S0094-1298(20)32396-8
  10. Bresnick SD. Management of a Common Breast Augmentation Complication: Treatment of the Double-Bubble Deformity With Fat Grafting. Annals of Plastic Surgery. 2016 Jan;76(1):18-22. PMID: 26101976; PMCID: PMC4679341. https://doi.org/10.1097/SAP.0000000000000553
  11. Abramo AC, Scartozzoni M, Lucena TW, Sgarbi RG. High- and Extra-High-Profile Round Implants in Breast Augmentation: Guidelines to Prevent Rippling and Implant Edge Visibility. Aesthetic Plast Surg. 2019;43(2): 305-312.  https://doi.org/10.1007/s00266-018-1264-1
  12. Tebbetts JB. A system for breast implant selection based on patient tissue characteristics and implant-soft tissue dynamics. Plast Reconstr Surg. 2002 Apr 01;109(4):1396-1409; discussion 1410-1415. PMID: 11964998. https://doi.org/10.1097/00006534-200204010-00030
  13. Frame J. The waterfall effect in breast augmentation. Gland Surg. 2017; 6(2):193-202.  https://doi.org/10.21037/gs.2016.10.01
  14. Chopra K, Gowda AU, Kwon E, Eagan M, Grant Stevens W. Techniques to Repair Implant Malposition after Breast Augmentation: A Review. Aesthet Surg J. 2016;36(6):660-671.  https://doi.org/10.1093/asj/sjv261
  15. Bachour Y, Verweij SP, Gibbs S. The aetiopathogenesis of capsular contracture: a systematic review of the literature. J Plast Reconstr Aesthet Surg. 2018;71(3):307-317.  https://doi.org/10.1016/j.bjps.2017.12.002
  16. Ajdic D, Zoghbi Y, Gerth D, Panthaki ZJ, Thaller S. The relationship of bacterial biofilms and capsular contracture in breast implants. Aesthet Surg J. 2016;36(3):297-309.  https://doi.org/10.1093/asj/sjv177
  17. Bachour Y, Bargon CA, de Blok CJM, Ket JCF, Ritt MJPF, Niessen FB. Risk factors for developing capsular contracture in women after breast implant surgery: A systematic review of the literature. J Plast Reconstr Aesthet Surg. 2018 Sept;71(9):e29-e48. Epub 2018 June 09. PMID: 29980456. https://doi.org/10.1016/j.bjps.2018.05.022
  18. Wagner DS, Mirhaidari SJ. Capsulectomy, implant exchange, and placement of acellular dermal matrix is effective in treating capsular contracture in breast augmentation patients. Aesthet Surg J. 2021;41(3):304-312.  https://doi.org/10.1093/asj/sjz358
  19. Ballard TN, Momoh AO. Advances in breast reconstruction of mastectomy and lumpectomy defects. Surg Oncol Clin N Am. 2014 July;23(3):525-548. Epub 2014 Apr 26. PMID: 24882349.
  20. Spear SL, Pittman T. A prospective study on lipoaugmentation of the breast. Aesthet Surg J. 2014;34:400-408.  https://doi.org/10.1177/1090820×13520449
  21. Kling RE, Mehrara BJ, Pusic AL, Young VL, Hume KM, Crotty CA, Rubin JP. Trends in Autologous Fat Grafting to the Breast: A National Survey of the American Society of Plastic Surgeons. Plast Reconstr Surg. 2013 July; 132(1):35-46. PMID: 23806907. https://doi.org/10.1097/prs.0b013e318290fad1
  22. Baxter R. Intracapsular allogenic dermal grafts for breast implant-related problems. Plast Reconstr Surg. 2003;112:1692-1696; discussion 1697-1698. https://doi.org/10.1097/01.prs.0000086365.25453.c3
  23. Voice SD, Carlsen LN. Using a capsular flap to correct breast implant malposition. Aesthet Surg J. 2001 Sept;21(5):441-444. PMID: 19331927. https://doi.org/10.1067/maj.2001.119123
  24. Flowers RS. Capsular contracture: prevention and cure (with attention to steroid related complications). In: Georgiade NG, ed. Aesthetic Breast Surgery. Philadelphia: Williams & Wilkins; 1983:95-109. 
  25. Rubin LR. The cushioned augmentation repair after a subcutaneous mastectomy. Plast Reconstr Surg. 1976;57:23-29.  https://doi.org/10.1097/00006534-197601000-00005
  26. Salibian MS, DiGregorio VR. A Simple Technique to Correct “Bottoming-out” of the Breast After Augmentation Mammaplasty. Aesthetic Surgery Journal. 2000 July;20(4):301-303.  https://doi.org/10.1067/maj.2000.109555
  27. King CA, Bartholomew AJ, Sosin M, Avila A, Famiglietti AL, Dekker PK, Perez-Alvarez IM, Song DH, Fan KL, Tousimis EA. A Critical Appraisal of Late Complications of Prepectoral versus Subpectoral Breast Reconstruction Following Nipple-Sparing Mastectomy. Ann Surg Oncol. 2021 Dec; 28(13):9150-9158. Epub 2021 Aug 12. PMID: 34386913. https://doi.org/10.1245/s10434-021-10085-z
  28. Farace F, Faenza M, Bulla A, Rubino C, Campus GV. Is mammary reconstruction with the anatomical Becker expander a simple procedure? Complications and hidden problems leading to secondary surgical procedures: a follow-up study. J Plast Reconstr Aesthet Surg. 2013 June;66(6):741-746. Epub 2013 Mar 09. PMID: 23478009. https://doi.org/10.1016/j.bjps.2013.02.004
  29. Wow T, Kolacinska-Wow A, Wichtowski M, et al. A retrospective study assessing the outcomes of immediate prepectoral and subpectoral implant and mesh-based breast reconstruction. Cancers (Basel). 2022;14:3188. https://doi.org/10.3390/cancers14133188
  30. Hartzell TL, Taghinia AH, Chang J, Lin SJ, Slavin SA. The use of human acellular dermal matrix for the correction of secondary deformities after breast augmentation: results and costs. Plast Reconstr Surg. 2010 Nov; 126(5):1711-1720. PMID: 21042128. https://doi.org/10.1097/prs.0b013e3181ef900c
  31. Ferraro GA, Lanzano G, Grella E, Gubitosi A, Nicoletti GF. Successful Treatment of Wound Dehiscence by Innovative Type 1 Collagen Flowable Gel: A Case Report. Plast Reconstr Surg Glob Open. 2022 June 20;10(6): e4360. PMID: 35747261; PMCID: PMC9208871. https://doi.org/10.1097/gox.0000000000004360
  32. Delay E, Garson S, Tousson G, Sinna R. Fat injection to the breast: technique, results, and indications based on 880 procedures over 10 years. Aesthet Surg J. 2009 Sept-Oct;29(5):360-376. PMID: 19825464. https://doi.org/10.1016/j.asj.2009.08.010
  33. Chasan PE. Breast capsulorrhaphy revisited: A simple technique for complex problems. Plast Reconstr Surg. 2005;115:296-301; discussion 302-303.  https://doi.org/10.1097/01.PRS.0000146706.85392.6F
  34. Spear SL, Bogue DP, Thomassen JM. Synmastia after breast augmentation. Plast Reconstr Surg. 2006;118:168S-171S; discussion 172S-174S. https://doi.org/10.1097/01.prs.0000246107.70668.97
  35. Spear SL, Dayan JH, Bogue D, Clemens MW, Newman M, Teitelbaum S, Maxwell GP. The “neosubpectoral” pocket for the correction of symmastia. Plast Reconstr Surg. 2009 Sept;124(3):695-703. PMID: 19363454. https://doi.org/10.1097/prs.0b013e3181a8c89d
  36. Parsa FD, Koehler SD, Parsa AA, Murariu D, Daher P. Symmastia after breast augmentation. Plastic and Reconstructive Surgery. 2011 Mar;127(3): 63e-65e. PMID: 21364388. https://doi.org/10.1097/PRS.0b013e31820635b5
  37. Cronin TD, Gerow FJ. Augmentation mammoplasty: A new ‘natural feel’ prosthesis. Transections of the Third International Congress of Plastic Surgery, Amsterdam. Excerpta Medical. 1964:41-49.  https://doi.org/10.1016/S0039-6109(16)39388-4
  38. U.S. Food and Drug Administration. Regulatory History of Breast Implants in the U.S.
  39. Hillard C, Fowler JD, Barta R, Cunningham B. Silicone breast implant rupture: a review. Gland Surg. 2017 Apr;6(2):163-168. PMID: 28497020; PMCID: PMC5409893. https://doi.org/10.21037/gs.2016.09.12
  40. Handel N, Garcia ME, Wixtrom R. Breast implant rupture: causes, incidence, clinical impact, and management. Plast Reconstr Surg. 2013 Nov; 132(5):1128-1137. PMID: 24165596. https://doi.org/10.1097/PRS.0b013e3182a4c243
  41. Everson LI, Parantainen H, Detlie T, Stillman AE, Olson PN, Landis G, Foshager MC, Cunningham B, Griffiths HJ. Diagnosis of breast implant rupture: imaging findings and relative efficacies of imaging techniques. AJR Am J Roentgenol. 1994 July;163(1):57-60. PMID: 8010248. https://doi.org/10.2214/ajr.163.1.8010248
  42. Dowden RV. Detection of gel implant rupture: a clinical test. Plast Reconstr Surg. 1993;91:548-550.  https://doi.org/10.1097/00006534-199303000-00025
  43. Hölmich LR, Fryzek JP, Kjøller K, Breiting VB, Jørgensen A, Krag C, McLaughlin JK. The diagnosis of silicone breast-implant rupture: clinical findings compared with findings at magnetic resonance imaging. Ann Plast Surg. 2005 June;54(6):583-589. PMID: 15900139. https://doi.org/10.1097/01.sap.0000164470.76432.4f
  44. Collis N, Sharpe DT. Silicone gel-filled breast implant integrity: a retrospective review of 478 consecutively explanted implants. Plast Reconstr Surg. 2000;105:1979-1985; discussion 1986-1989. https://doi.org/10.1097/00006534-200005000-00010
  45. Amoresano A, De Stefano L, Rea I, Pane F, Birolo L, Schonauer F. Chemical and Structural Characterization of Several Mid-Term Explanted Breast Prostheses. Materials (Basel). 2016 Aug 09;9(8):678. PMID: 28773799; PMCID: PMC5510735. https://doi.org/10.3390/ma9080678
  46. Janszen G, Arnoldi M, Vinci V, Klinger M, Di Landro L. On the Safety of Implanted Breast Prostheses in Accidental Impacts. Materials (Basel). 2023 July 04;16(13):4807. PMID: 37445121; PMCID: PMC10343374. https://doi.org/10.3390/ma16134807

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.