The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Safonova T.N.

FGBU "NII glaznykh bolezneĭ" RAMN, Moskva

Sikach E.I.

Research Institute of Eye Diseases, 11A Rossolimo St., Moscow, Russian Federation, 119021

Ozheredov I.A.

Lomonosov Moscow State University, 1 Leninskiye Gory, Moscow, Russian Federation, 119991

Current methods of tear film stability assessment

Authors:

Safonova T.N., Sikach E.I., Ozheredov I.A.

More about the authors

Journal: Russian Annals of Ophthalmology. 2019;135(5): 92‑98

Read: 337 times


To cite this article:

Safonova TN, Sikach EI, Ozheredov IA. Current methods of tear film stability assessment. Russian Annals of Ophthalmology. 2019;135(5):92‑98. (In Russ.)
https://doi.org/10.17116/oftalma201913505192

Recommended articles:
Evaluation of the effi­ciency of combined pharmaco-physiotherapy in patients with dry eye syndrome. Problems of Balneology, Physiotherapy and Exercise Therapy. 2024;(6-2):91-95

References:

  1. Safonova TN, Pateyuk LS. Ocular surface system integrity. Vestnik oftal’mologii. 2015;131(1):96-103. (In Russ.) https://doi.org/10.17116/oftalma2015131196-102
  2. Wolffsohn JS, Arita R, Chalmers R, Djalilian A, Dogru M, Dumbleton K, Gupta PK, Karpecki P, Lazreg S, Pult H, Sullivan BD, Tomlinson A, Tong L, Villani E, Yoon KC, Jones L, Craig JP. TFOS DEWS II Diagnostic Methodology report. The Ocular Surface. 2017;15(3):539- 574. https://doi.org/10.1016/j.jtos.2017.05.001
  3. Brzheskij VV, Egorova GB, Egorov EA. Sindrom «suhogo glaza» i zabolevaniya glaznoj poverhnosti: klinika, diagnostika, lechenie. M.: GEHOTAR-Media; 2016. (In Russ.)
  4. Kanellopoulos AJ, Asimellis G. In pursuit of objective dry eye screening clinical techniques. Eye and Vision. 2016;3:1. https://doi.org/10.1186/s40662-015-0032-4
  5. Mooi JK, Wang MT, Lim J, Muller A, Craig JP. Minimising instilled volume reduces the impact of fluorescein on clinical measurements of tear film stability. Contact Lens and Anterior Eye. 2017;40(3):170-174. https://doi.org/10.1016/j.clae.2017.01.004
  6. Johnson ME, Murphy PJ. Measurement of ocular surface irritation on a linear interval scale with the ocular comfort index. Investigative Ophthalmology and Visual Science. 2007;48(10):4451-4458. https://doi.org/10.1167/iovs.06-1253
  7. Abelson RL, Lane KJ, Rodriguez J, Johnston P, Angjeli E, Ousler G, Montgomery D. A single-center study evaluating the effect of the controlled adverse environment (CAE(SM)) model on tear film stability. Clinical Ophthalmology. 2012;6:1865-1872. https://doi.org/10.2147/opth.s33905
  8. Sullivan BD, Crews LA, Sonmez B, Paz MF, Comert E, Charoenrook V. Clinical utility of objective tests for dry eye disease: variability over time and implications for clinical trials and disease management. Cornea. 2012;31(9):1000-1008. https://doi.org/10.1097/ico.0b013e318242fd60
  9. Ramos L, Barreira N, Mosquera A, Penedo MG, Yebra-Pimentel E, García-Resúa C. Analysis of parameters for the automatic computation of the tear film break-up time test based on CCLRU standards. Computer Methods and Programs in Biomedicine. 2014;113:715-724. https://doi.org/10.1016/j.cmpb.2013.12.003
  10. Goto E, Tseng SC. Differentiation of lipid tear deficiency dry eye by kinetic analysis of tear interference images. Archives of Ophthalmology. 2003;121(2):173-180. https://doi.org/10.1001/archopht.121.2.173
  11. Finis D, Pischel N, Schrader S, Geerling G. Evaluation of lipid layer thickness measurement of the tear film as a diagnostic tool for Meibomian gland dysfunction. Cornea. 2013;32(12):1549-1553. https://doi.org/10.1097/ico.0b013e3182a7f3e1
  12. Licznerski TJ, Kasprzak HT, Kowalik W. Analysis of shearing interferograms of tear film using fast fourier transforms. Journal of Biomedical Optics. 1998;3(1):32-37. https://doi.org/10.1117/1.429886
  13. Szczesna DH, Iskander DR. Robust estimation of tear film surface quality in lateral shearing interferometry. Journal of Biomedical Optics. 2009;14(6):064039. https://doi.org/10.1117/1.3275474
  14. Szczesna-Iskander DH, Iskander DR, Read SA, Alonso-Caneiro D. Noninvasive in vivo assessment of soft contact lens type on tear film surface quality. Investigative Ophthalmology and Visual Science. 2012;53(1):525-531. https://doi.org/10.1167/iovs.11-8257
  15. Goto T, Zheng X, Okamoto S, Ohashi Y. Tear film stability analysis system: introducing a new application for videokeratography. Cornea. 2004;23(8 suppl):65-70. https://doi.org/10.1016/s0002-9394(02)02221-3
  16. Gumus K, Crockett CH, Rao K, Yeu E, Weikert MP, Shirayama M, Hada S, Pflugfelder SC. Noninvasive assessment of tear stability with the tear stability analysis system in tear dysfunction patients. Investigative Ophthalmology and Visual Science. 2011;52(1):456-461. https://doi.org/10.1167/iovs.10-5292
  17. Hong J, Sun X, Wei A, Cui X, Li Y, Qian T, Wang W, Xu J. Assessment of tear film stability in dry eye with a newly developed keratograph. Cornea. 2013;32(5):716-721. https://doi.org/10.1097/ico.0b013e3182714425
  18. Abdelfattah NS, Dastiridou A, Sadda SR, Lee OL. Noninvasive imaging of tear film dynamics in eyes with ocular surface disease. Cornea. 2015;34(suppl 10):48-52. https://doi.org/10.1097/ico.0000000000000570
  19. Montes-Mico R, Caliz A, Alio JL. Wavefront analysis of higher order aberrations in dry eye patients. Journal of Refractive Surgery. 2004;20:243-247.
  20. Alonso-Caneiro D, Iskander DR, Collins MJ. Tear film surface quality with soft contact lenses using dynamic-area high-speed videokeratoscopy. Eye and Contact Lens. 2009;35:227-231. https://doi.org/10.1097/icl.0b013e3181b3350f
  21. Kopf M, Yi F, Iskander DR, Collins MJ, Shaw AJ, Straker B. Tear film surface quality with soft contact lenses using dynamic videokeratoscopy. Journal of Optometry. 2008;1:14-21. https://doi.org/10.3921/joptom.2008.14
  22. Downie LE. Automated tear film surface quality breakup time as a novel clinical marker for tear hyperosmolarity in dry eye disease. Investigative Ophthalmology and Visual Science. 2015;56(12):7260-7268. https://doi.org/10.1167/iovs.15-17772
  23. Maslennikov VI, Koskin SA, Shelepin YuG, Yan AV. O novom metode issledovaniya otrazhajushej sposobnosti rogovicy. Sovremennaya optometrja. 2013;9(69):28-31. (In Russ.)
  24. Nichols JJ, Nichols KK, Puent B, Saracino M, Mitchell GL. Evaluation of tear film interference patterns and measures of tear break-up time. Optometry and Vision Science. 2002;79(6):363-369. https://doi.org/10.1097/00006324-200206000-00009
  25. Cho P, Douthwaite W. The relation between invasive and noninvasive tear break-up time. Optometry and Vision Science. 1995;72(1):17-22. https://doi.org/10.1097/00006324-199501000-00004
  26. Craig JP, Singh I, Tomlinson A, Morgan PB. The role of tear physiology in ocular surface temperature. Eye. 2000;14(Pt 4):635-641. https://doi.org/10.1038/eye.2000.156
  27. Purslow C, Wolffsohn J. The relation between physical properties of the anterior eye and ocular surface temperature. Optometry and Vision Science. 2007;84(3):197-201. https://doi.org/10.1097/opx.0b013e3180339f6e
  28. Kamao T, Yamaguchi M, Kawasaki S, Mizoue S, Shiraishi A, Ohashi Y. Screening for dry eye with newly developed ocular surface thermographer. American Journal of Ophthalmology. 2011;151:782-791. https://doi.org/10.1016/j.ajo.2010.10.033
  29. Su TY, Hwa CK, Liu PH, Wu MH, Chang DO, Su PF, Chang SW, Chiang HK. Noncontact detection of dry eye using a custom designed infrared thermal image system. Journal of Biomedical Optics. 2011;16:046009. https://doi.org/10.1117/1.3562964
  30. Abreau K, Callan C, Kottaiyan R, Zhang A, Yoon G, Aquavella JV, Zavislan J, Hindman HB. Temperatures of the ocular surface, lid, and periorbital regions of Sjogren’s, evaporative, and aqueous-deficient dry eyes relative to normals. The Ocular Surface. 2016;14(1):64-73. https://doi.org/10.1016/j.jtos.2015.09.001
  31. Su TY, Chang SW, Yang CJ, Chiang HK, Ho WT, Chang SW, Chiang HK. Thermographic evaluation of tear film break-up time to study tear film stability. The International Journal of Thermal Sciences. 2014;99:36-40. https://doi.org/10.1016/j.ijthermalsci.2015.07.032
  32. Li W, Graham AD, Selvin S, Lin MC. Ocular surface cooling corresponds to tear film thinning and breakup. Optometry and Vision Science. 2015;92:248-256. https://doi.org/10.1097/opx.0000000000000672
  33. Versura P, Giannaccare G, Fresina M, Campos EC. Subjective discomfort symptoms are related to low corneal temperature in patients with evaporative dry eye. Cornea. 2015;34(9):1079-1085. https://doi.org/10.1097/ico.0000000000000512
  34. Willcox MDP, Argüeso P, Georgiev GA, Holopainen JM, Laurie GW, Millar TJ, Papas EB, Rolland JP, Schmidt TA, Stahl U, Suarez T, Subbaraman LN, Uçakhan OÖ, Jones L. TFOS DEWS II Tear Film Report. The Ocular Surface. 2017;15(3):366-403. https://doi.org/10.1016/j.jtos.2017.03.006
  35. Abusharha AA, Pearce EI. The effect of low humidity on the human tear film. Cornea. 2013;32:429-434. https://doi.org/10.1097/ico.0b013e31826671ab
  36. Hamano H, Hori M, Mitsunaga S. Measurement of evaporation rate of water from the precorneal tear film and contact lenses. Contacto. 1981;25(2):7-14.
  37. Trees GR, Tomlinson A. Effect of artificial tear solutions and saline on tear film evaporation. Optometry and Vision Science. 1990;67:886-890. https://doi.org/10.1097/00006324-199012000-00002
  38. Rolando M, Refojo MF. Tear evaporimeter for measuring water evaporation rate from the tear film under controlled conditions in humans. Experimental Eye Research. 1983;36(1):25-33. https://doi.org/10.1016/0014-4835(83)90086-6
  39. Rolando M, Refojo MF, Kenyon KR. Increased tear evaporation in eyes with keratoconjunctivitis sicca. Archives of Ophthalmology. 1983;101:557-558. https://doi.org/10.1001/archopht.1983.01040010557003
  40. Tsubota K, Yamada M. Tear evaporation from the ocular surface. Investigative Ophthalmology and Visual Science. 1992;33(10):2942-2950.
  41. Tomlinson A, Cedarstaff TH. Tear evaporation from the human eye: the effects of contact lens wear. Journal of the British Contact Lens Association. 1982;5:141-144. https://doi.org/10.1016/s0141-7037(82)80012-8
  42. Craig JP, Tomlinson A. Importance of the lipid layer in human tear film stability and evaporation. Optometry and Vision Science. 1997;74:8-13. https://doi.org/10.1016/s0892-8967(97)90017-1
  43. Mathers WD, Binarao G, Petroll M. Ocular water evaporation and the dry eye. A new measuring device. Cornea. 1993;12(4):335-340. https://doi.org/10.1097/00003226-199307000-00010
  44. Mathers WD, Daley TE. Tear flow and evaporation in patients with and without dry eye. Ophthalmology. 1996;103(4):664-669. https://doi.org/10.1016/s0161-6420(96)30637-4
  45. Guillon M, Maissa C. Contact lens wear affects tear film evaporation. Eye and Contact Lens. 2008;34(6):326-330. https://doi.org/10.1097/icl.0b013e31818c5d00
  46. Craig JP, Willcox MD, Argüeso P, Maissa C, Stahl U, Tomlinson A, Wang J, Yokoi N, Stapleton F; members of TFOS International Workshop on Contact Lens Discomfort. The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee. Investigative Ophthalmology and Visual Science. 2013;54(11): TFOS123-156. https://doi.org/10.1167/iovs.13-13235
  47. Abusharha AA, Pearce EI, Fagehi R. Effect of ambient temperature on the human tear film. Eye and Contact Lens. 2016;42(5):308-312. https://doi.org/10.1097/icl.0000000000000210
  48. Uchiyama E, Aronowicz JD, Butovich IA, McCulley JP. Increased evaporative rates in laboratory testing conditions simulating airplane cabin relative humidity: an important factor for dry eye syndrome. Eye and Contact Lens. 2007;33(4):174-176. https://doi.org/10.1097/01.icl.0000252881.04636.5e
  49. Wojtowicz JC, McCulley JP. Assessment and impact of the time of day on aqueous tear evaporation in normal subjects. Eye and Contact Lens. 2009;35(3):117-119. https://doi.org/10.1097/icl.0b013e31819c2963
  50. Petznick A, Tan JH, Boo SK, Lee SY, Acharya UR, Tong L. Repeatability of a new method for measuring tear evaporation rates. Optometry and Vision Science. 2013;90(4):366-371. https://doi.org/10.1097/opx.0b013e318288bdd1
  51. Rohit A, Ehrmann K, Naduvilath T, Willcox M, Stapleton F. Validating a new device for measuring tear evaporation rates. Ophthalmic and Physiological Optics. 2014;34(1):53-62. https://doi.org/10.1111/opo.12096
  52. Tan JH, Ng EYK, Acharya UR. Evaluation of tear evaporation from ocular surface by functional infrared thermography. Medical Physics. 2010;37(11):6022-6034. https://doi.org/10.1118/1.3495540
  53. Purslow C, Wolffsohn JS, Santodomingo-Rubido J. The effect of contact lens wear on dynamic ocular surface temperature. Contact Lens and Anterior Eye. 2005;28(1):29-36. https://doi.org/10.1016/j.clae.2004.10.001
  54. Mittleman D, ed. Sensing with terahertz radiation. Springer Berlin Heidelberg. 2003;117-153. https://doi.org/10.1007/978-3-540-45601-8
  55. Bennett DB, Taylor ZD, Tewari P, Singh RS, Culjat MO, Grundfest WS, Sassoon DJ, Johnson RD, Hubschman JP, Brown ER. Terahertz sensing in corneal tissues. Journal of Biomedical Optics. 2011;16(5):057003. https://doi.org/10.1117/1.3575168
  56. Taylor ZD, Garritano J, Sung S, Bajwa N, Bennett DB, Nowroozi B, Tewari P, Sayre JW, Hubschman JP, Deng SX, Brown ER, Grundfest WS. THz and mm-wave sensing of corneal tissue water content: In vivo sensing and imaging results. IEEE Transactions on Terahertz Science and Technology. 2015;5(2):184-196. https://doi.org/10.1109/tthz.2015.2392628
  57. Angeluts AA, Balakin AV, Mishchenko MD, Ozheredov IA, Prokopchuk MN, Saphonova TN, Shkurinov AP. Application of THz reflectometry to eye cornea hydration measurements. 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz). 2016. https://doi.org/10.1109/irmmw-thz.2016.7758909
  58. Ozheredov IA, Prokopchuk MN, Mischenko MD, Safonova TN, Solyankin PM, Larichev AV, Angeluts AA, Balakin AV, Shkurinov AP. In vivo THz sensing of the cornea of the eye. Laser Physics Letters. 2018;15(5):055601. https://doi.org/10.1088/1612-202x/aaac76
  59. Bron AJ, Abelson MB, Ousler G, Pearce E, Tomlinson A, Yokoi N. Methodologies to diagnose and monitor dry eye disease: report of the diagnostic methodology subcommittee of the international Dry Eye Workshop. The Ocular Surface. 2007;5(2):108-152. https://doi.org/10.1016/s1542-0124(12)70083-6
  60. Yokoi N, Komuro A. Non-invasive methods of assessing the tear film. Experimental Eye Research. 2004;78:399-407. https://doi.org/10.1016/j.exer.2003.09.020
  61. Foulks GN. Challenges and pitfalls in clinical trials of treatments for dry eye. The Ocular Surface. 2003;1:20-30. https://doi.org/10.1016/s1542-0124(12)70004-6
  62. Bron AJ, Evans VE, Smith JA. Grading of corneal and conjunctival staining in the context of other dry eye tests. Cornea. 2003;22(7):640-650. https://doi.org/10.1097/00003226-200310000-00008
  63. Nichols KK, Nichols JJ, Mitchell GL. The lack of association between signs and symptoms in patients with dry eye disease. Cornea. 2004;23(8):762-770. https://doi.org/10.1097/01.ico.0000133997.07144.9

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.