The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Avetisov K.S.

FGBU "NII glaznykh bolezneĭ" RAMN

Bakhchieva N.A.

Research Institute of Eye Diseases, 11 A, B, Rossolimo St., Moscow, Russia, 119021

Avetisov S.É.

FGBU "Nauchno-issledovatel'skiĭ institut glaznykh bolezneĭ" RAMN, Moskva

Novikov I.A.

Institute of Cardiology named after A.L. Myasnikov of National Medical Research Center for Cardiology, Moscow, Russia

Belikov N.V.

Bauman Moscow State Technical University, 5/12-aya Baumanskaya, Moscow, Russia, 105005

Khaidukova I.V.

State educational institution of higher professional education «South Ural State Medical University», Russian Ministry of Health, Chelyabinsk, Russian Federation

n.s.i.n.i.V. Biomechanical aspects of anterior capsulotomy in cataract surgery

Authors:

Avetisov K.S., Bakhchieva N.A., Avetisov S.É., Novikov I.A., Belikov N.V., Khaidukova I.V.

More about the authors

Journal: Russian Annals of Ophthalmology. 2017;133(3): 82‑88

Read: 927 times


To cite this article:

Avetisov KS, Bakhchieva NA, Avetisov SÉ, Novikov IA, Belikov NV, Khaidukova IV. n.s.i.n.i.V. Biomechanical aspects of anterior capsulotomy in cataract surgery. Russian Annals of Ophthalmology. 2017;133(3):82‑88. (In Russ.)
https://doi.org/10.17116/oftalma2017133382-88

Recommended articles:
Sele­ctive asse­ssment of biomechanical properties of the lens capsule. Russian Annals of Ophthalmology. 2024;(6):15-23

References:

  1. Fisher RF. Elastic constants of the human lens capsule. J Physiol. 1969;201:1-19. https://doi.org/10.1113/jphysiol.1969.sp008739 
  2. Fisher RF. Wakely J. The elastic constants and ultrastructural organization of a basement membrane (Lens Capsule). Proc R Soc. 1976;193:335-358. https://doi.org/10.1098/rspb.1976.0051
  3. Fisher RF. Hayes BP. Thickness and volume constants and ultrastructural organization of basement membrane (Lens Capsule). J Physiol. 1979;293:229-245. https://doi.org/10.1113/jphysiol.1979.sp012887 
  4. Krag S, Olsen T, Andreassen T. Biomechanical Characteristics of the Human Anterior Lens Capsule in Relation to Age. Invest Ophthalmol Vis Sci. 1997;38:357-363.
  5. Danielson CC. Tensile mechanical and creep properties of Descemet’s membrane and lens capsule. Exp Eye Res. 2004;79:343-350. https://doi.org/10.1016/j.exer.2004.05.014
  6. Pedrigi RM, David G, Dziezyc J, Humphrey JD. Regional mechanical properties and stress analysis of the human anterior lens capsule. Vis Res. 2007;47:1781-1789. https://doi.org/10.1016/j.visres.2007.03.014 
  7. Gassmann F, Schimmelpfennig B, Kloti R. Anterior capsulotomy by means of bipolar radio-frequency endodiathermy. J. Cataract Refract Surg. 1988;14:673-676. https://doi.org/10.1016/s0886-3350(88)80040-3 
  8. Gimbel HV, Neuhann T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990;16:31-37. https://doi.org/10.1016/s0886-3350(13)80870-x 
  9. Krag S, Thim K, Corydon L. Diathermic capsulotomy versus capsulorhexis: a biomechanical study. J Cataract Refract Surg. 1997;23:86-90. https://doi.org/10.1016/s0886-3350(97)80156-3
  10. Al Harthi K, Al Shahwan S, Al Towerki A, Banerjee P, Behrens A, Edward D. Comparison of the anterior capsulotomy edge created by manual capsulorhexis and 2 femtosecond laser platforms: Scanning electron microscopy study. J Cataract Refract Surg. 2014;40(12):2106-2112. https://doi.org/10.1016/j.jcrs.2014.10.001
  11. Bala C, Xia Y, Meades K. Electron microscopy of laser capsulotomy edge: Interplatform comparison. J Cataract Refract Surg. 2014;40(8):1382-1389. https://doi.org/10.1016/j.jcrs.2013.11.045 
  12. Mastropasqua L, Toto L, Calienno R, Mattei P, Mastropasqua A, Vecchiarino L, Di Iorio D. Scanning electron microscopy evaluation of capsulorhexis in femtosecond laser-assisted cataract surgery. J Cataract Refract Surg. 2013;39(10):1581-1586. https://doi.org/10.1016/j.jcrs.2013.06.016 
  13. Ostovic M, Klaproth O, Hengerer F, Mayer W, Kohnen T. Light microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser-assisted and manual anterior capsulotomy. J Cataract Refract Surg. 2013;39(10):1587-1592. https://doi.org/10.1016/j.jcrs.2013.07.024
  14. Schultz T, Joachim S, Tischoff I, Dick H. Histologic evaluation of in vivo femtosecond laser-generated capsulotomies reveals a potential cause for radial capsular tears. Eur J Ophthalmol. 2015;25(2):112-118. https://doi.org/10.5301/ejo.5000484 
  15. Avetisov K, Fedorov A, Novikov I. Light and scanning electron microscopy of anterior lens capsule following different capsulorhexis techniques. Vestnik oftal’mologii. 2015;131(6):4-10. (In Russ.). https://doi.org/10.17116/oftalma201513164-10
  16. Lua RM, Oertle P, Camenzind L et al. Superior Rim Stability of the Lens Capsule Following Manual Over Femtosecond Laser Capsulotomy. Inv Opthalmol & Vis Sci. 2016; 57:2839-2849. https://doi.org/10.1167/iovs.15-18355
  17. Krag S., Andreassen Т. Biomechanical Measurements of the Porcine Lens Capsule. Exp Eye Res. 1996;62:253-260. https://doi.org/10.1006/exer.1996.0030
  18. Friedman NJ, Palanker DV, Schuele G et al. Femtosecond laser capsulotomy. J Cataract Refract Surg. 2011;37:1189-1198.
  19. Auffarth GU, Reddy KP, Ritter R et al. Comparison of the maximum applicable stretch force after femtosecond laser-assisted and manual anterior capsulotomy. J Cataract Refract Surg. 2013;39:105-109. https://doi.org/10.1016/j.jcrs.2012.08.065
  20. Sandor GL, Kiss Z, Bocskai ZI et al. Comparison of the Mechanical Properties of the Anterior Lens Capsule Following Manual Capsulorhexis and Femtosecond Laser Capsulotomy. J Cataract Refract Surg. 2014;30:660-664. https://doi.org/10.3928/1081597x-20140903-08 
  21. Young WC, Budynas RG. The behavior of bodies under stress. In: Young WC, Budinas RG, eds. Roark’s Formulas for Stress and Strain. 7th ed. New York: McGraw-Hill; 2002:54.
  22. Sandor GL, Kiss Z, Bocskai ZI et al. Evaluation of the Mechanical Properties of the Anterior Lens Capsule Following Femtosecond Laser Capsulotomy at Differrent Pulse Energy Settings. J Cataract Refract Surg. 2015;31:153-157. https://doi.org/10.3928/1081597x-20150220-02 
  23. Packer M, Teuma Valas E, Glasser A, Bott S. Defining the ideal femtosecond laser capsulotomy. Br J Ophthalmol. 2015;0:1-6. https://doi.org/10.1136/bjophthalmol-2014-306065
  24. Barraquer RL, Michael R, Abreu R et al. Human lens capsule thickness as a function of age and location along the sagittal lens perimeter. Invest Ophthalmol Vis Sci. 2006;407:2053-2060. https://doi.org/10.1167/iovs.05-1002 
  25. Kuzak JR, Brown HG. Embryology and anatomy of the lens. In: Albert DM, Jakobiaec FA eds. Principles and practice in ophthalmology. Philadelphia: WB Saunders. 1994:82-96.
  26. Andreo LK, Wilson ME, Apple DJ. Elastic properties and scanning electron microscopic appearance of manual continuous curvilinear capsulorhexis and vitrectorhexis in an animal model of pediatric cataract. J Cataract Refract Surg. 1999;25:534-539. https://doi.org/10.1016/s0886-3350(99)80051-0
  27. Pedrigi RM, Dziezyc J, Humphrey JD. Altered mechanical behavior and properties of the human anterior lens capsule after cataract surgery. Exp Eye Res. 2009;89:575-580. https://doi.org/10.1016/j.exer.2009.06.001 
  28. Shigemitsu T, Ishiguro K, Shimisu Y. Immunocytochemical features of lens after cataract tissue-signaling molecules growth factors, cytokines, other signaling molecules), cytoskeleton proteins, cellular and extracellular matrix proteins. Int Ophathalmol. 1999;23:137-144. 
  29. Werner L, Jia G, Sussman G et al. Mechanized model to assess capsulorhexis resistance to tearing. J Cataract Refract Surg. 2010;36:1954-1959. https://doi.org/10.1016/j.jcrs.2010.05.026
  30. Thompson VM, Berdahl JP, Solano JM, Chang DF. Comparison of Manual, Femtosecond Laser and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver Eyes. Ophthalmology. 2016;123:265-274. https://doi.org/10.1016/j.ophtha.2015.10.019 

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.