The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Eolchiian S.A.

NII neĭrokhirurgii im. N.N. Burdenko RAMN, Moskva

Complex skull defects reconstruction with САD/САМ titanium and polyetheretherketone (PEEK) implants

Authors:

Eolchiian S.A.

More about the authors

Journal: Burdenko's Journal of Neurosurgery. 2014;78(4): 3‑13

Read: 8079 times


To cite this article:

Eolchiian SA. Complex skull defects reconstruction with САD/САМ titanium and polyetheretherketone (PEEK) implants. Burdenko's Journal of Neurosurgery. 2014;78(4):3‑13. (In Russ., In Engl.)

Recommended articles:

References:

  1. Antonov A.N., Evseev A.V., Kamaev S.V. et al. Laser stereolithography – a technology of layered manufacturing of three-dimensional objects from liquid photopolymerizable compositions. Opticheskaya Tekhnika 1998; 1: 3: 5-14. In Russian.
  2. Eolchiyan S.A., Potapov A.A., Serova N.K. et al. Reconstructive surgery of cranio-orbital injuries. Vopr Neirokhir 2011; 75: 2: 25-40. In Russian.
  3. Kravchuk A.D., Potapov A.A., Likhterman L.B., Zakharova N.E. Reconstructive surgery of skull defects. Reconstructive and minimally invasive surgery for effects of traumatic brain injury. Eds.: A.N. Konovalov, A.A. Potapov, L.B. Likhterman et al. Moscow 2012; 118-157. In Russian.
  4. Potapov A.A., Kornienko V.N., Kravchuk A.D. et al. Modern technologies in surgical treatment of effects of skull and brain injury. Vestnik RAMN 2012; 9: 31-37. In Russian.
  5. Satanin L.A. Clinical picture, diagnosis, and surgical treatment of patients with fibrous dysplasia of the bones of the calvarium and skull base: Candidate of Medicine Thesis. Moscow 2012. In Russian.
  6. Brown S.A., Hastings R.S., Mason J.J., Moet A. Characterization of short-fibre reinforced thermoplastics for fracture fixation devices. Biomaterials 1990; 11: 541-547.
  7. Cabraja M., Klein M., Lehmann T.N. Long-term results following titanium cranioplasty of large skull defects. Neurosurg Focus 2009; 26: 6. E10. - doi: 10.3171/2009.3.FOCUS091.
  8. Camarini E.T., Tomeh J.K., Dias J.K., da Silva E.J. Reconstruction of Frontal Bone Using Specific Implant Polyether-Ether-Ketone. J Craniofac Surg 2011; 22: 6: 2205-2207.
  9. Cheng A.C., Wee A.G. Reconstruction of cranial bone defects using alloplastic implants produced from a stereolithographically-generated cranial mo-del. Ann Acad Med Singapore 1999; 28: 5: 692-696.
  10. D’Urso P.S., Earwaker W.J., Barker T.M. et al. Custom cranioplasty using stereolithography and acrylic. Br J Plast Surg 2000; 53: 200-204.
  11. Dujovny M., Evenhouse R., Anger C. et al. Pre-formed prosthesis from computed tomography data: repair of large cranial defects. In.: Calvarial and dural reconstruction: Neurosurgical topics. Eds. S. Com-Rengachary, E. Bensel. AANS Publ 1998; 77-87.
  12. Eppley B.L. Craniofacial reconstruction with computer-generated HTR patient-matched implants: Use in primary bony tumor excision. J Craniofac Surg 2002; 13: 5: 650-657.
  13. Eufinger H., Wittkampf A.R., Wehmoller M., Zonneveld F.W. Single-step fronto-orbital resection and reconstruction with individual resection template and corresponding titanium implant: a new method of computer-aided surgery. J Craniomaxillofac Surg 1998; 26: 6: 373-378.
  14. Eufinger H., Wehmoller M. Microsurgical tissue transfer and individual computer-aided designed and manufactured prefabricated titanium implants for complex craniofacial reconstruction. Scand J Plast Reconstr Surg Hand Surg 2002; 36: 326-331.
  15. Eufinger H., Weihe S., Scherer P. et al. Management of cranial and craniofacial bone defects with prefabricated individual titanium implants: follow-up and evaluation of 166 patients with 169 titanium implants from 1994 to 2000. Int J Comp Ass Radiol Surg 2006; 1: 4: 197-203.
  16. Eschbach L. Nonresorbable polymers in bone surgery. Injury 2000; 31: 22-27.
  17. Fallahi B., Foroutan M., Motavalli S., Dujovny M., Limaye S. Computer-aided manufacturing of implants for the repair of large cranial defects: an improvement of the stereolithography technique. Neurol Res 1999; 21: 281-286.
  18. Jalbert F., Boetto S., Nadon F. et al. One-step primary reconstruction for complex craniofacial resection with PEEK custom-made implants. J Cranio-Maxillo-Facial Surg 2013; http://dx.doi.org/10.1016/j.jcms.2013.04. 001.
  19. Joffe J., Harris M., Kahugu F. et al. A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome. Br J Neurosurg 1999; 13: 576-580.
  20. Kurtz S.M., Devine J.N. PEEK Biomaterials in Trauma, Orthopedic, and Spinal Implants. Biomaterials 2007; 28: 4845-4869.
  21. Kuttenberger J.J., Hardt N. Long-term results following reconstruction of craniofacial defect with titanium micro-mesh system. J Craniomaxillofac Surg 2001; 29: 75-81. DOI: 10.1054/jcms.2001.0197.
  22. Lethaus B., Ter Laak M.P., Laeven P. et al. A treatment algorithm for patients with large skull bone defects and first results. J Craniomaxillofac Surg 2011; 39: 6: 435-440.
  23. PEEK-OPTTIMA Polymer Processing Guide. Invibio Ltd: Thornton-Cleveleys UK 2004; 1-14.
  24. Poukens J., Laeven P., Beerens M. et al. A classification of cranial implants based on the degree of difficulty in computer design and manufacture. Int J Med Robotics Comput Ass Surg 2008; 4: 46-50.
  25. Puppa A., Mottaran R., Scienza R. Image-guided cranial osteoma resection and bioceramic porous hydroxyapatite custom-made reconstruction in a one-step surgical procedure. Technical notes and illustrative case. Acta Neurochir 2010; 152: 1: 155-159.
  26. Rotaru H., Stan H., Florian I.S. et al. Cranioplasty with custom-made implants: analyzing the cases of 10 patients. J Oral Maxillofac Surg 2012; 70: 2: 169-176. doi: 10.1016/j.joms.2011.09.036.
  27. Scolozzi P., Martinez A., Jaques B. Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant. J Craniofac Surg 2007; 18: 1: 224-228.
  28. Schlegel J., Green S. Polyetheretherketones (PEEK) - A biocompatible high performance plastic. Med Plast 2002; 14: 12.1-12.10.
  29. Staffa G., Barbanera A., Faiola A. et al. Custom made bioceramic implants in complex and large cranial reconstruction: A two-year follow-up. J Craniomaxillofac Surg 2011; doi:10.1016/j.jcms.2011.04.014.
  30. Tessier P. Autogenous bone grafts taken from the calvarium for facial and cranial applications. Clin Plast Surg 1982; 9: 531-538.
  31. Yaremchuk M. Acquired cranial bone deformities in Plastic surgery 2-nd ed. Ed. S.J. Mathes. Saunders Elsevier 2006; 547-563.
  32. William D.F., McNamara A. Potential of polyetheretherketone (PEEK) and carbon-fibre-reinforced PEEK in medical application. J Mater Sci Lett 1987; 6: 188-190.

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.