Management of hemolyzed specimens

Authors:

Lippi G., Cervellin G., Favaloro E.J., Plebani M.

More about the authors

Journal: Laboratory Service. 2017;6(2): 38‑46

Read: 20704 times


To cite this article:

Lippi G, Cervellin G, Cervellin G, Favaloro EJ, Favaloro EJ, Plebani M, Plebani M. Management of hemolyzed specimens. Laboratory Service. 2017;6(2):38‑46. (In Russ.)
https://doi.org/10.17116/labs20176238-46

References:

  1. National Committee for Clinical Laboratory Standards. Reference and Selected Procedures for the Quantitative Determination of Hemoglobin in Blood; Approved Standard, 3rd ed. NCCLS document H15-A3. Wayne, PA: NCCLS; 2000.
  2. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. doi:10.1016/S0140-6736(86)90837-8
  3. Bland M. An Introduction to Medical Statistics. 3rd ed. New York: Oxford University Press; 2000, 405 р.
  4. Hanneman SK. Design, analysis, and interpretation of method-comparison studies. AACN Advanced Critical Care. 2008;19:223-234. doi:10.1097/01.aacn.0000318125.41512.a3
  5. Lima-Oliveira G, Salvagno GL, Lippi G, Montagnana M, Pitanguiera Manguera CS, et al. New ways to deal with known preanalytical issues: use transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Biochem Med. 2011;412:152-159. doi:10.11613/bm.2011.024
  6. Lima-Oliveira G, Salvagno GL, Lippi G, Montagnana M, Scartezini M, Picheth G et al. Eliminating of the venous stasis error for routine coagulation testing by transillumination. Clin Chim Acta. 2011;412:1482-1484. doi:10.1016/j.cca.2011.04.008
  7. Frey AM. Drawing blood samples from vascular access devices: evidence-based practice. J Infus Nurs. 2003;26:285-293. doi:10.1097/00129804-200309000-00004
  8. Lippi G, Luca Salvagno G, Blanckaert N, Giavarina D, Green S, Kitchen S, et al. Multicenter evaluation of the hemolysis index in automated clinical chemistry systems. Clin Chem Lab Med. 2009;47:934-939. doi:10.1515/cclm.2009.218
  9. Miller WG, Erek A, Cunningham TD, Oladipo O, Scott MG, Johnson RE. Commutability limitation influence quality control results with different reagent lots. Clin Chem. 2011;57:76-83. doi:10.1373/clinchem.2010.148106
  10. Vermeer HJ, Steen G, Naus AJ, Goevaerts B, Agricola PT, Schoenmakers CH. Correction of patient results for Beckman Coulter LX-20 assays by interference due hemoglobin, bilirubin or lipids: a practical approach. Clin Chem Lab Med. 2007;45:114-119. doi:10.1515/cclm.2007.004
  11. Jeffery J, Sharma A, Ayling RM. Detection of haemolysis and reporting of potassium results in samples from neonates. Ann Clin Biochem. 2009;46(Pt3):222-225. doi:10.1258/acb.2009.008241
  12. Owens H, Siparsky G, Bajaj L, Hampers LC. Correction of factitious hyperkalemia in hemolysed specimens. Am J Emerg Med. 2005;23:872-875. doi:10.1016/j.ajem.2005.05.011
  13. Hawkins R. Variability in potassium/hemoglobin ratios for hemolysis correction. Clin Chem. 2002;48:796. doi:10.1515/cclm.2005.037
  14. Brescia V, Tampoia M, Mileti A. Evaluation of fractious hyperkalemia in hemolytic samples: impact of mean corpuscular hemoglobin concentration. Lab Med. 2009;40:224-226. doi:10.1309/lmq6yy4q1vkvrphs
  15. Dimeski G, Clague AE, Hickman PE. Correction and reporting of potassium results in haemolysed samples. Ann Clin Biochem. 2005;42:119-123. doi:10.1258/0004563053492739
  16. Shepherd J, Warner MH, Poon P, Kilpatrick ES. Use haemolysis index to estimate potassium concentration in in-vitro haemolysed serum samples. Clin Chem Lab Med. 2006;44:877-879. doi:10.1515/cclm.2006.140
  17. Carraro P. Potassium report of hemolysed serum samples. Clin Chem Lab Med. 2008;46:425. doi:10.1515/cclm.2008.087
  18. Favaloro EJ, Lippi G. Laboratory reporting of hemostasis assays: the final post-analytical opportunity to reduce errors of clinical diagnosis in hemostasis? Clin Chem Lab Med. 2010;48:309-321. doi:10.1515/cclm.2010.061
  19. Lippi G, Banfi G, Buttarello M, Ceriotti F, Daves M, Dolci A, et al. Recommendations for detection and management of unsuitable samples in clinical laboratories. Clin Chem Lab Med. 2007;45:728-736. doi:10.1515/cclm.2007.174
  20. World Health Organization. Use of anticoagulants in diagnostic laboratory: stability of blood, plasma and serum samples. Geneva: WHO; 2002.
  21. Salinas M, Flores E, Lugo J, Lopez Garrigos M. Reporting test results in hemolysed samples from primary care patients. Clin Biochem. 2009;42:1204. doi:10.1016/j.clinbiochem.2009.02.019

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.