The site of the Media Sphera Publishers contains materials intended solely for healthcare professionals.
By closing this message, you confirm that you are a certified medical professional or a student of a medical educational institution.

Tarichko Iu.V.

Kafedra gospital'noĭ khirurgii s kursom detskoĭ khirurgii RUDN, Moskva

Baranovich V.Yu.

Peoples' Friendship University of Russia, Moscow;
N.A. Semashko Central Clinical Hospital №2 Public Corporation “Russian Railways”, Moscow

Maksimkin D.A.

Central Town Clinical Hospital, Reutov, Moscow Region, Department of Cardiovascular Surgery, Peoples’ Friendship University of Russia, Moscow, Russia, Clinic for Aortic and Cardiovascular Surgery, I.M. Sechenov First Moscow State Medical University

Illarionova E.V.

Kafedra gospital'noĭ khirurgii Rossiĭskogo universiteta druzhby narodov, Moskva

Veretnik G.I.

Kafedra gospital'noĭ khirurgii Rossiĭskogo universiteta druzhby narodov, Moskva

Faibushevich A.G.

Kafedra gospital'noĭ khirurgii RUDN, Moskva;
NUZ TsKB #2 im. N.A. Semashko OAO "RZhD", Moskva

Surgical manipulations in patients with permanent pacemaker

Authors:

Tarichko Iu.V., Baranovich V.Yu., Maksimkin D.A., Illarionova E.V., Veretnik G.I., Faibushevich A.G.

More about the authors

Journal: Pirogov Russian Journal of Surgery. 2010;(4): 11‑15

Read: 20115 times


To cite this article:

Tarichko IuV, Baranovich VYu, Maksimkin DA, Illarionova EV, Veretnik GI, Faibushevich AG. Surgical manipulations in patients with permanent pacemaker. Pirogov Russian Journal of Surgery. 2010;(4):11‑15. (In Russ.)

Recommended articles:

References:

  1. Bokeriya L.A. Takhiaritmii. M 1989; 294.
  2. Bokeriya L.A., Revishvili A.Sh. Interventsionnaya i khirurgicheskaya aritmologiya: sovremennoe sostoyanie i perspektivy razvitiya. Med tekhnika 2002; 6: 7-8.
  3. Bokeriya L.A., Revishvili A.Sh., Mitin D.D. i dr. Implantatsiya EKS v Rossii v 2002 godu. Vestn aritmol 2004; 224: 236.
  4. Vedenina I.V., Blinov S.A. Predoperatsionnaya podgotovka i anesteziya u bol'nykh s kardiostimulyatorami pri vnekardial'nykh operatsiyakh. Ros med zhurn 2005; 4: 27.
  5. Vinogradov V.V., Panfilov B.K. Kholetsistektomiya u bol'nykh s iskusstvennym voditelem ritma. Khirurgiya 1984; 7: 134-135.
  6. Glukhov V.I., Vizichkach V.P., Vishnyak V.V. Uspeshnoe udalenie 2/3 zheludka po povodu yazvennoi bolezni zheludka s penetratsiei v podzheludochnuyu zhelezu u bol'nogo s IVR. Sbornik nauch. trudov prakticheskogo zdravookhraneniya Primorskogo kraya i kafedry VGMU, posvyashchennyi 95-letiyu gor. bol'nitsy g. Spasska-Dal'nego. Spassk-Dal'nii 2000; 25.
  7. Zhdanov A.M., Gukov A.O., Termosesov S.A. Klinicheskii opyt ispol'zovaniya EKS s razlichnymi vidami serdechnoi nedostatochnosti. Aktual'nye voprosy khirurgii: Sb. nauchn. trudov, posvyashchennyi 50-letiyu Instituta khirurgii im. A.V. Vishnevskogo RAMN 1995; 116-123.
  8. Keosanov A.Kh. Obshchekhirurgicheskie operatsii u bol'nykh s korrigirovannoi bradisistoliei v razlichnye sroki posle implantatsii iskusstvennogo voditelya ritma: Dis. … kand. med. nauk. M 2005; 109.
  9. Kostyleva O.V. Narusheniya ritma u bol'nykh s elektricheskoi stimulyatsiei serdtsa. Voprosy differentsial'noi diagnostiki i lecheniya: Dis. … kand. med. nauk. M 1991; 193.
  10. Mazur I.A., Zhdanov A.M., Chigineva V.V. i dr. Dvukhkamernaya EKS pri gipertroficheskoi kardiomiopatiii. Kardiologiya 1997; 37: 8: 36-40.
  11. Milonov O.B., Got'e S.V., Smirnov V.A. i dr. Kholetsistektomiya u bol'nykh s bradiaritmicheskimi narusheniyami v usloviyakh postoyannoi elektrokardiostimulyatsii. Khirurgiya 1985; 5: 95-99.
  12. Nechitailo M.E., Skums A.V. Uspeshnoe udalenie gigantskoi zlokachestvennoi leiomiomy zheludka u bol'nogo s iskusstvennym voditelem ritma. Vestn khir 1991; 10: 44-45.
  13. Fedorov V.D., Drogaitsev A.D., Ryabov G.A. i dr. Khirurgicheskie operatsii u bol'nykh s implantirovannym elektrokardiostimulyatorom. Khirurgiya 1985; 8: 116-120.
  14. Fedorov I.V., Sigal E.I., Odintsov V.V. Endoskopicheskaya khirurgiya pod red. Savel'eva V.S. M: Geotar Meditsina 1998; 351.
  15. Khirmanov V.N., Shal'dakh M., Yuzenkevich S.A. Vozmozhnosti sovremennoi elektrokardiotimulyatsii v lechenii serdechnoi nedostatochnosti. Serdechnaya nedostatochnost' 2001; 2: 5: 228-230.
  16. Shul'man V.A., Egorov D.F., Matyushin G.V. i dr. Sindrom slabosti sinusovogo uzla. St-Peterburg 1995; 446.
  17. Bourke M.E. The patient with a pacemaker or related device. Can J Anaesth 1996; 43: 5: 4-41.
  18. Chauvin M., Crenner F., Brechenmacher C. Interaction between permanent cardiac pacing and electrocautery: the significance of electrode position. Pacing Clin Electrophysiol 1992; 15: 11: 2028-2033.
  19. Dreifus L.S., Fisch C., Griffin J.C. et al. Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. J Am Coll Cardiol 1991; 18: 1-13.
  20. Gendahl H. Pacemaker follow-up with prolonged intervals in the stable period 1 to 5 years postimplant. Pacing Clin Electrophysiol 1996; 19: 1219-1224.
  21. Godin J.F., Petitot J.C. STIMAREC report. Pacemaker failures due to electrocautery and external electric shock. Pacing Clin Electrophysiol 1989; 12: 6: 1001.
  22. Grobety M., Perret F., Schlaepfer J. et al. Cardiac pacemaker dysfunction secondary to outside interference: a review. Schweiz Med Wochenschr 1996; 126: 17: 723-733.
  23. Habicht J.M., Stulz P. Electrocoagulation in patients with cardiac pacemakers: what should be considered? Chirurg 1995; 66: 8: 774-779.
  24. Heller L.I. Surgical electrocautery and the runaway pacemaker syndrome. Pacing Clin Electrophysiol 1990; 13: 9: 1084-1085.
  25. Hoffmann J.L., Zimmermann M. Cardiac pacing in 2005. Rev Med Suisse 2005; 1: 9: 600-605.
  26. Leung S.K., Lau Ch.-P., Lau T.-Ch. et al. Sinus-sensor rate difference: a novel metod to evaluate dual sensor pacemakers. Eur JCPE 1996; 6: 1: 5: 200.
  27. Mangar D., Atlas G.M., Kane P.B. Electrocautery - induced pacemaker malfunction during surgery. Can J Anaesth 1991; 38: 5: 616-618.
  28. Matzke T.J., Christenson L.J., Christenson S.D. et al. Pacemakers and implantable cardiac defibrillators in dermatologic surgery. Dermatol Surg 2006; 32: 9: 1155-1162.
  29. Meller J.E., Simonsen E.H., Mcller M. Impact of continues quality improvement on selection of pacing mode and rate of complications in permanent pacing. Heart 1997; 77: 357-362.
  30. Peters R.W., Gold M.R. Reversible prolonged pacemaker failure due to electrocautery. J Interv Card Electrophysiol 1998; 2: 4: 343-344.
  31. Sebben J.E. Electrosurgery and cardiac pacemakers. J Am Acad Dermatol 1983; 9: 3: 457-463.
  32. Sweesy M., Erickson S., Johnson D. et al. How often do follow-up visits result in reprogramming? Eur JCPE 1996; 6: 1: 5: 194.
  33. Veitch A., Fairclough P. Endoscopic diathermy in patients with cardiac pacemakers. Endoscopy 1998; 30: 6: 544-547.
  34. Werner P., Charbit B., Samain E. et al. Interference between a dual-chamber pasemaker and argon electrocautery device during hepatectomy. Ann Fr Anaesth Reanim 2001; 20: 8: 716-719.

Email Confirmation

An email was sent to test@gmail.com with a confirmation link. Follow the link from the letter to complete the registration on the site.

Email Confirmation

We use cооkies to improve the performance of the site. By staying on our site, you agree to the terms of use of cооkies. To view our Privacy and Cookie Policy, please. click here.